15A NCAC 02T .1111. MONITORING AND REPORTING  


Latest version.
  • (a)  Representative samples of residuals that are prepared for application to the land or placed in a surface disposal unit shall be collected and analyzed.

    (b)  The analytical methods listed in 40 CFR 503.8(b) as stated on January 1, 1996 shall be incorporated into this Section by reference.

    (c)  Residuals applied to the land or placed in a surface disposal unit shall be monitored for pollutants as listed in Rule .1105(a) and Rule .1105(d) of this Section as well as Rule .1106 and Rule .1107 as applicable at the frequency as stipulated in the following:

     

                                    Metric Tons per 365 day period                                       Monitoring Frequency

                                            (Dry Weight Basis)     

                                    Greater than zero but less than 290                                        Once per year

                       Equal to or greater than 290 but less than 1,500            Once per quarter (four times per year)

                    Equal to or greater than 1,500 but less than 15,000          Once per 60 days (six times per year)

                                  Equal to or greater than 15,000                                Once per month (12 times per year)

     

    (d)  A report of all monitoring and reporting requirements as specified in the permit shall be submitted to the Division by the permittee annually on or before March 1st of each calendar year.

    (e)  All records shall be retained for a minimum of five years.

     

History Note:        Authority G.S. 143-215.1; 143-215.3(a);

Eff. September 1, 2006.